![]() The first step for hatching is choosing best fertilized eggs. If you do, the loss of humidity will cause the eggshells of the unhatched eggs to dry out and they won’t able to break through the egg. (this is very important to ensure that the eggshells are soft enough forġ0- Don’t open the lid frequently when the chicks start to hatch, you could fill water through kettle. (this will also rest the egg turning countdown back to 1:59)ħ- Keep an eye on the humidity reading and fill the water channels when needed.Ĩ- At day 18 you should remove the tray with the turning mechanism and place the eggs on top of he bottom grid.ĩ- At the same time it is important to fill water channels to increase the ![]() These are settings I have never adjusted or attempted to adjust as the heating unit starts and stops within I O C of my set temperature of 37.6 0C.ġ- Test your incubator to see if it functions properly.Ģ- Connect the egg turner plug to the control plug inside the egg compartment.ģ- Fill one or both water channels depending on local humidity levels.Ĥ- Set the eggs with the pointy side down.ĥ- Close the lid and switch on the incubator.Ħ- Press the reset button (left green button) to reset and start the day counter from “0”. This is to prevent accidental out of range temperature setting. ![]() If HS is set as 38.2 and LS is set as 37.4, then the desire temperature (incubating temperature adjustment) can only be changed from 38.2 to 37.4, so the minimum temperature shall be limited to 37.2 even if the is kept on pressing. HS - (High Set) and LS - (Low Set) set the limit of the setting range of the desired temperature setting (incubating temperature adjustment) Note that the adjustment is the difference between the thermometer readings and should be adjusted with if the temperature reading of the incubator is to high and normal value (indicating + value) if the incubator reading is too low.Ħ- Temperature Upper and lower limit set (HS and LS) (CA)ĥ-3- Push "+" or - until code "CA" appears in the temperature screen.ĥ-5- Push "+" or - to adjust to the correct measurement. The reading given by the thermometer can be adjusted if you find that the temperature reading is incorrect using a calibrated thermometer.ĥ-1- Calibrating the temperature sensor measurement. The thermometer correct reading is set at OOC. I tend to fill both my water channels every 4 to 5 days and at day 18 when I remove the egg trays I over fill them to increase the humidity to about 65%.ĥ- Calibrating temperature sensor reading (CA) By filling both water channels the humidity should rise to 60% dependant on the local humidity levels and the time of year. (AS)Ĥ-3- Push “+” or “-“ until code “AS” appears in the temperature screen.Ĥ-5- Push "+" or - to adjust to your desired lower alarm setting. This is sufficient and you don't need to make any changes to these settings.Ĥ-1- Low humidity alarm parameter setting. The humidity alarm is factory set to sound at 45% humidity. (AL)ģ-1-1- Press and hold “temperature setting” for 3 sec.ģ-1-2- Push “+” or “-“ until code “AL” appears in the temperature screen.ģ-1-4- Push “+” or “-“ to adjust to your desired lower alarm setting.ģ-2- Higher temperature alarmparameter setting (AH)ģ-2-1- Press and hold “temperature setting” for 3 sec.ģ-2-2- Push “+” or “-“ until code “AH” appears in the temperature screen.ģ-2-4- Push “+” or “-“ to adjust to your desired higher alarm setting.Ĥ- Humidity alarm parameter settings_(AS) This is sufficient and you do not need to make any changes to these settings.ģ-1- Low temperature alarmparameter setting. The temperature alarm is factory set to sound at 1oC over or below the set temperature. I recommend you set the temperature at 37.6oC.ģ- Temperature alarm parameter settings (AL and AH) ![]() These incubators are factory set at 38oC, I found the chicks hatch at day 19 to 20 meaning the temperature being to high. 1- Testing your incubator for the first time: 1-1- Connect the egg turner plug to the control plug.ġ-2- Connect the provided power wire to your power source.ġ-5- You will hear an alarm sounding due to low temperature/humidity, it’s normal, don’t worry.ġ-6- Press any button to cancel the alarm.ġ-7- Operate the incubator and filling the water hole you will notice the humidity reading increase.ġ-8- Press reset button to check the automatic egg turning function.lt turns every two hours,lasting 10 seconds.Ģ- Setting the temperature 2-1- Push "SET" once.Ģ-2- Push “+” or “-“ to select the desired temperature. ![]()
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |